Rockwell Disclaimer: The product is used surplus. Urgent Automation is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Urgent Automation is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, Urgent Automation makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Urgent Automation also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. Urgent Automation also makes no representations as to your right to install any such firmware on the product. Urgent Automation will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.


ED3225

Description: The Eaton ED3225 Molded Case Circuit Breaker is in the C Series and has 3 Pole(s). The module has 225 Trip Amps and a Thermal-Magnetic Trip Unit.

Urgent Automation is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply.

Product comes with Urgent Automation's 1-year warranty.


Description: The Eaton ED3225 Molded Case Circuit Breaker is in the C Series and has 3 Pole(s). The module has 225 Trip Amps and a Thermal-Magnetic Trip Unit.


Rated 4.8 with 10 reviews







About ED3225

The ED3225 is a 225 Amps complete molded case Westinghouse/Cutler Hammer circuit breaker. The circuit breaker is ideal for use with reverse fed applications. The ED3225 only has load side lug terminals and its trip mechanism cannot be individually replaced. If the trip mechanism is faulty, the whole unit should be replaced. The ED3225 is a Type ED Series C circuit breaker with a temperature rating of 40 degrees Celsius and it supports instantaneous and LI-long-time trip functions. The ED3225 has 3 poles, a voltage rating of 240 Volts AC, 125 Volts DC, and a thermal magnetic trip protection type. The ED3225 molded case circuit breaker from Eaton has an AIC rating of 65 kA at 240 Volts AC, and 10 kA at 125 Volts DC. The circuit breaker uses bolt-on connections (Cable In and Cable Out) and it is panel or DIN rail mountable.

The ED3225 measures 3.38 inches by 4.13 inches by 4.13 inches and it is UL listed. The circuit breaker meets the NEMA SABS 156, SEV 157, IEC 157-1, BS 4752, AS 2184, and the AB1 standards. The ED3225 is purposely manufactured for commercial applications. The ED3225 Westinghouse circuit breaker, as with other Series C molded case circuit breakers, does not provide for the field installations of internal components. The Series C breakers are meant to provide a prolonged service life without maintenance. However, regular inspections should be performed, ensuring that the tripping mechanism is manually tested to check for delay times. Malfunctions during inspection call for a replacement of the whole unit.


Technical specifications:


Part Number/Catalog No.ED3225
Product TypeMolded Case Circuit Breaker
SeriesC
FrameF
Pole(s)3
Trip Amps65 kA @ 240V
Interrupting Capacity4.5 lb
WeightThermal-Magnetic
Trip Unit4.13 x 6 x 3.38 in.
Part Number/Catalog No.ED3225
Product TypeMolded Case Circuit Breaker
SeriesC
FrameF
Pole(s)3
Trip Amps65 kA @ 240V
Interrupting Capacity4.5 lb
WeightThermal-Magnetic
Trip Unit4.13 x 6 x 3.38 in.