EHD2050

Preowned

Includes a 1-Year UrgentAutomation warranty.

UrgentAutomation is not an authorized distributor for Eaton Cutler-Hammer.

Rated 5 with 20 reviews

UrgentAutomation sells surplus and refurbished products which are sourced through independent channels. All warranties and support, if applicable, are with UrgentAutomation and not the manufacturer. UrgentAutomation is not an authorized distributor or representative for the listed manufacturers and makes no representations as to any quality control performed by any listed manufacturer on the products. The products listed on this website may vary as to their country of origin; the accessories, and other items included with the product; and the language used on the packaging, the parts, and any related instructions or printed material related to the products. This website is not sanctioned or approved by any manufacturer or tradename listed. Designated trademarks, brand names and brands appearing herein are the property of their respective owners. Read More


EHD2050

Description: The Eaton EHD2050 Molded Case Circuit Breaker is in the C Series and has 2 Pole(s). The module has 50 Trip Amps and a Thermal-Magnetic Trip Unit.

Preowned

Includes a 1-Year UrgentAutomation warranty.

UrgentAutomation is not an authorized distributor for Eaton Cutler-Hammer.


Description: The Eaton EHD2050 Molded Case Circuit Breaker is in the C Series and has 2 Pole(s). The module has 50 Trip Amps and a Thermal-Magnetic Trip Unit.


Rated 5 with 20 reviews







About EHD2050

The EHD2050 is an Eaton Cutler-Hammer Series C complete molded case circuit breaker (MCCB) with a 50 Amps current rating. The continuous current rating of the EHD2050 is the amount of current that this MCCB can carry in the open air. This value is linked to the operating temperature value. For ambient temperatures of over 40 degrees, this current rating is slightly reduced. This thermal-magnetic circuit breaker is suitable for High Intensity Discharge (HID). The interrupting rating for this MCCB is 18 kAIC at 240 Volts AC and 14 kAIC at 480 Volts AC. The interrupt rating of the circuit breaker always decreases when the voltage increases. Users should pay attention to the interrupt rating because it is the most crucial factor in the breaker selection process.

This value must be synchronized with the users’ applications because it is the amount of fault current that this device can safely interrupt without being damaged. The Eaton Cutler-Hammer EHD2050 2-pole MCCB has a push-to-trip mechanism which allows the users to test the trip mechanism by manual means. The device is packed inside of an F frame housing that has dimensions of 3.38 inches x 2.75 inches x 6.00 inches (86 millimeters x 70 millimeters x 152 millimeters). The EHD2050 has terminals on the load side. It can be connected to a maximum of 480 Volts AC or 250 Volts DC. The MCCB’s trip mechanism is controlled by fixed thermal and fixed magnetic trip controls. These 2 trip types protect the electrical installation from overcurrents and short-circuits.


Technical specifications:


Part Number/Catalog No.EHD2050
Product TypeMolded Case Circuit Breaker
SeriesC
FrameF
Pole(s)2
Trip Amps18 kA @ 240V
Interrupting Capacity3 lb
WeightThermal-Magnetic
Trip Unit2.75 x 6 x 3.38 in.
Part Number/Catalog No.EHD2050
Product TypeMolded Case Circuit Breaker
SeriesC
FrameF
Pole(s)2
Trip Amps18 kA @ 240V
Interrupting Capacity3 lb
WeightThermal-Magnetic
Trip Unit2.75 x 6 x 3.38 in.
Common misspellings:
  • EHD2o50
  • EHD205o