FD4045

Urgent Automation is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply.

Product comes with Urgent Automation's 1-year warranty.

Rated 4.8 with 10 reviews

Rockwell Disclaimer: The product is used surplus. Urgent Automation is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Urgent Automation is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, Urgent Automation makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Urgent Automation also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. Urgent Automation also makes no representations as to your right to install any such firmware on the product. Urgent Automation will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.


FD4045

Description: The Eaton FD4045 Molded Case Circuit Breaker is in the C Series and has 4 Pole(s). The module has 45 Trip Amps and a Thermal-Magnetic Trip Unit.

Urgent Automation is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply.

Product comes with Urgent Automation's 1-year warranty.


Description: The Eaton FD4045 Molded Case Circuit Breaker is in the C Series and has 4 Pole(s). The module has 45 Trip Amps and a Thermal-Magnetic Trip Unit.


Rated 4.8 with 10 reviews







About FD4045

The Eaton Cutler-Hammer FD4045 Molded Case Circuit Breaker is a thermal-magnetic circuit breaker in the Series C, Frame F line of completely assembled circuit breakers with only load side terminals, used for circuit overload protection in a wide range of low voltage systems. It is designed to provide conductors and connected electrical appliances with instantaneous protection, and it is rated for reverse feed use and HARC rated applications. The FD4045 has a continuous current rating of 45 Amps, with an interrupt rating of 35 KAIC and is designed for ranges of applications with 600 Volt AC maximum line operating voltage. This breaker consists of a sealed enclosure, a non-interchangeable trip unit, load end only terminals, an operating mechanism. The terminal is a UL rated Copper/Aluminium steel with 4 to 50 millimeter square wire range designed to meet nominal load rating.

The FD4045 trip unit consists of non-adjustable trip elements, which provide thermal trip action using currently heated bimetal, and a magnetic trip action using electromagnet connected in series. In the event that the circuit current exceeds the nominal value, a trip free operating mechanism prevent contacts from being held closely together, and this operating mechanism indicates the breaker’s position (an advantage in systems with multiple breakers). The FD404 is designed to provide 80% rating below a 40 degree Celsius temperature limit, and it is built to operate within a 0 to 95% non-corrosive and non-condensing relative humidity condition. The FD4045 has IEC, UL, and CSA certifications, and is shipped with a net weight of 6.0 pounds and an aggregate volume of 5.5 x 6.0 x 3.4 inches.


Technical specifications:


Part Number/Catalog No.FD4045
Product TypeMolded Case Circuit Breaker
SeriesC
FrameF
Pole(s)4
Trip Amps35 kA @ 277V
Interrupting Capacity6 lb
WeightThermal-Magnetic
Trip Unit5.5 x 6 x 3.38 in.
Part Number/Catalog No.FD4045
Product TypeMolded Case Circuit Breaker
SeriesC
FrameF
Pole(s)4
Trip Amps35 kA @ 277V
Interrupting Capacity6 lb
WeightThermal-Magnetic
Trip Unit5.5 x 6 x 3.38 in.