KT2225T

Preowned

Includes a 1-Year UrgentAutomation warranty.

UrgentAutomation is not an authorized distributor for Eaton Cutler-Hammer.

Rated 4.9 with 5 reviews

UrgentAutomation sells surplus and refurbished products which are sourced through independent channels. All warranties and support, if applicable, are with UrgentAutomation and not the manufacturer. UrgentAutomation is not an authorized distributor or representative for the listed manufacturers and makes no representations as to any quality control performed by any listed manufacturer on the products. The products listed on this website may vary as to their country of origin; the accessories, and other items included with the product; and the language used on the packaging, the parts, and any related instructions or printed material related to the products. This website is not sanctioned or approved by any manufacturer or tradename listed. Designated trademarks, brand names and brands appearing herein are the property of their respective owners. Read More


KT2225T

Description: The KT2225T Trip Unit operates with 2 Poles and 225 Amps. The Thermal-Magnetic Trip Unit is in the C Series and has a 1.5 lbs Weight.

Preowned

Includes a 1-Year UrgentAutomation warranty.

UrgentAutomation is not an authorized distributor for Eaton Cutler-Hammer.


Description: The KT2225T Trip Unit operates with 2 Poles and 225 Amps. The Thermal-Magnetic Trip Unit is in the C Series and has a 1.5 lbs Weight.


Rated 4.9 with 5 reviews







About KT2225T

The Eaton Cutler-Hammer KT2225T is a trip unit with 2 poles that can be installed in C Series molded case circuit breakers with K Frames. It is applicable for 225 Amps rated systems and it satisfies the UL-489 standard requirements. The Eaton KT2225T is an interchangeable trip unit that has a thermal element with the time delay on the overload and an adjustable magnetic trip that offers protection against short circuits. The KT2225T trip unit is calibrated at 40 degrees Celsius and its housing is factory sealed to disable the tampering option. This calibrated nominal device current that the trip unit can carry continuously is marked on the nameplate of the trip unit. Note that according to the NEC requirements, protective devices like molded case circuit breakers should not be loaded with more than 80% of the nominal current rating.

The users should not connect cables to the MCCB or supply it with the power until they install the KT2225T into it. Inspect the trip unit for visible signs of damage before integrating it with the circuit breaker frame. On the load side of the frame, remove the plastic protective covers and push the trip unit upwards until the trip unit is correctly seated in the base. Check the latch bracket pin. It should be properly placed in its slots. To position the trip unit easily, the users can push the circuit breaker lever to the closed position. To finish the installation process, use a hexagonal-head wrench to screw in and tighten the retaining screws of the trip unit (the screws on both poles). Put protective plastic barriers on the trip unit.


Technical specifications:


Part Number/Catalog No.KT2225T
Product TypeTrip Unit
SeriesC
FrameK
Poles2
Amps225
Unit TypeThermal-Magnetic
Continuous Current Range55 to 400 Amps
Dimensions (W x H x D)5.5 x 10.13 x 4.1 inches
Weight1.5 pounds
Part Number/Catalog No.KT2225T
Product TypeTrip Unit
SeriesC
FrameK
Poles2
Amps225
Unit TypeThermal-Magnetic
Continuous Current Range55 to 400 Amps
Dimensions (W x H x D)5.5 x 10.13 x 4.1 inches
Weight1.5 pounds