UrgentAutomation sells surplus and refurbished products which are sourced through independent channels. All warranties and support, if applicable, are with UrgentAutomation and not the manufacturer. UrgentAutomation is not an authorized distributor or representative for the listed manufacturers and makes no representations as to any quality control performed by any listed manufacturer on the products. The products listed on this website may vary as to their country of origin; the accessories, and other items included with the product; and the language used on the packaging, the parts, and any related instructions or printed material related to the products. This website is not sanctioned or approved by any manufacturer or tradename listed. Designated trademarks, brand names and brands appearing herein are the property of their respective owners. Read More


LD4500

Description: The Eaton LD4500 Molded Case Circuit Breaker operates with 4 Poles and 500 Amps. The module has a L Frame and a Thermal-Magnetic Unit Type.

Preowned

Includes a 1-Year UrgentAutomation warranty.

UrgentAutomation is not an authorized distributor for Eaton Cutler-Hammer.


Description: The Eaton LD4500 Molded Case Circuit Breaker operates with 4 Poles and 500 Amps. The module has a L Frame and a Thermal-Magnetic Unit Type.


Rated 4.9 with 17 reviews







About LD4500

The Eaton LD4500 is a complete Series C circuit breaker. It has 4 poles and 500 Amps of current rating. An integrated and interchangeable thermal-magnetic trip unit is provided with the LD4500. The voltage ratings for the breaker are 250 Volts DC and 600 Volts AC. The interrupting capacity specifications are 22 kAIC at 250 Volts DC, 25 kAIC at 600 Volts AC, 35 kAIC at 480 Volts AC, and 65 kAIC at 240 Volts AC. The LD4500 is an LD type of circuit breaker with terminals. Important precautions need to be followed during installation and maintenance of the breaker and these include clearing the work area of high voltages and putting the breaker in the off state.

The Eaton Series C molded case circuit breakers such as the LD4500 are designed to provide many years of maintenance-free operation. Despite this, it is recommended to carry out limited amounts of field inspection and field testing on a periodic basis. During the inspection, the breaker must be in the off state. Checks to be performed during inspection include removing moisture, dust, and grease from the breaker surface, checking mechanical linkages by switching the breaker on and off a few times, checking the mechanical tripping function by pressing the push-to-trip button, checking the wire connecting terminals and the other types of bus bar connectors for looseness or for signs of overheating, and checking the breaker mounting hardware. The L Frame LD4500 has the following dimensions: 10.75 inches in height, 11.00 inches in width, and 4.06 inches in depth.


Technical specifications:


Part Number/Catalog No.LD4500
Product TypeMolded Case Circuit Breaker
SeriesC
FrameL
Poles4
Amps500
Interrupting Capacity65 kAIC at 240 Volts AC
Unit TypeThermal-Magnetic
Dimensions (W x H x D)11 x 10.75 x 4.06 inches
Weight25 pounds
Part Number/Catalog No.LD4500
Product TypeMolded Case Circuit Breaker
SeriesC
FrameL
Poles4
Amps500
Interrupting Capacity65 kAIC at 240 Volts AC
Unit TypeThermal-Magnetic
Dimensions (W x H x D)11 x 10.75 x 4.06 inches
Weight25 pounds
Common misspellings:
  • 1D4500
  • LDA500
  • LD45o0
  • LD450o