UrgentAutomation sells surplus and refurbished products which are sourced through independent channels. All warranties and support, if applicable, are with UrgentAutomation and not the manufacturer. UrgentAutomation is not an authorized distributor or representative for the listed manufacturers and makes no representations as to any quality control performed by any listed manufacturer on the products. The products listed on this website may vary as to their country of origin; the accessories, and other items included with the product; and the language used on the packaging, the parts, and any related instructions or printed material related to the products. This website is not sanctioned or approved by any manufacturer or tradename listed. Designated trademarks, brand names and brands appearing herein are the property of their respective owners. Read More


NGS308033E

Description: The Eaton NGS308033E Molded Case Circuit Breaker operates with 3 Poles and 80 Amps. It also has Imperial tapped line/load conductor Terminations and a 600 V Rated Operational Voltage.

Preowned

Includes a 1-Year UrgentAutomation warranty.

UrgentAutomation is not an authorized distributor for Eaton Cutler-Hammer.


Description: The Eaton NGS308033E Molded Case Circuit Breaker operates with 3 Poles and 80 Amps. It also has Imperial tapped line/load conductor Terminations and a 600 V Rated Operational Voltage.


Rated 4.6 with 20 reviews







About NGS308033E

The NGS308033E is a 690 Volts AC standard molded case circuit breaker from Eaton Cutler-Hammer. The circuit breaker has 800 Amps of rated current and 3 poles. The NGS308033E measures 9 x 16 x 6 inches. The circuit breaker uses an NG-frame type, it has an adjustable long delay pickup, and it is HACR rated. This NGS308033E contains an imperial tapped line and load conductors and it belongs to Series G of the molded case circuit breakers. The NGS308033E is UL and CSA listed. The NGS308033E Eaton circuit breaker has an interrupt capacity of 85 kAIC at 240 Volts AC, 50 kAIC at 480 Volts AC, and 25 kAIC at 600 Volts AC.

The net weight for the NGS308033E stands at 47 pounds while the trip unit for the circuit breaker is a Digitrip 310+ Electronic LS. The conducting paths for the NGS308033E have 750 Volts AC insulation voltage, and there are 690 Volts AC insulation voltage for the auxiliary circuits, and an 8 kiloVolts rated impulse withstand voltage for the main conducting paths while the auxiliary circuits have an impulse withstand voltage of 4-kiloVolts. The Cutler-Hammer NGS308033E is 80% rated. Also, the circuit breaker is factory-sealed, making field installations of internal components impossible. The NGS308033E, having an NG-frame, accommodates external accessories like base mounting hardware, interphase barriers, a key interlock kit, an electrical operator, a handle extension, and a trip LED module, among others. Some of these external accessories are pole specific for proper functioning.


Technical specifications:


Part Number/Catalog No.NGS308033E
Product TypeMolded Case Circuit Breaker
FrameNG
kAIC @ 480 VAC50
Poles3
Amps80
Trip Unit310+ Electronic LS
TerminationsImperial tapped line/load conductor
Max. Rated Current1200 A
Main Conducting Paths750 VAC
Max. Switching Frequency60 1/h
Rated Making Capacity20 A
Max. Opening Time62 ms
Rated Operational Voltage600 V
Part Number/Catalog No.NGS308033E
Product TypeMolded Case Circuit Breaker
FrameNG
kAIC @ 480 VAC50
Poles3
Amps80
Trip Unit310+ Electronic LS
TerminationsImperial tapped line/load conductor
Max. Rated Current1200 A
Main Conducting Paths750 VAC
Max. Switching Frequency60 1/h
Rated Making Capacity20 A
Max. Opening Time62 ms
Rated Operational Voltage600 V