Rockwell Disclaimer: The product is used surplus. Urgent Automation is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Urgent Automation is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, Urgent Automation makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Urgent Automation also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. Urgent Automation also makes no representations as to your right to install any such firmware on the product. Urgent Automation will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.


HLD3600T106W

Description: The Eaton HLD3600T106W Molded Case Circuit Breaker operates with 3 Poles and 600 Amps. The module has a L Frame and a OPTIM Unit Type.

Urgent Automation is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply.

Product comes with Urgent Automation's 1-year warranty.


Description: The Eaton HLD3600T106W Molded Case Circuit Breaker operates with 3 Poles and 600 Amps. The module has a L Frame and a OPTIM Unit Type.


Rated 4.9 with 6 reviews







About HLD3600T106W

The Eaton Cutler-Hammer HLD3600T106W is an HLD type of electronic molded case circuit breaker housed in an L frame. The device supports automating trip activity when it detects a ground fault or an overcurrent condition. The trip will happen as the result of a shunt or an undervoltage condition too. This MCCB features the toggle handle operating mechanism. The handle is automatically moved to the middle (trip) position and it serves as a switching position indicator. The handle can be moved from this position manually to off or the on positions. The electronic trip unit installed in this module is the OPTIM 1050 that performs the LSIG type of trip. This means that the HLD3600T106W has adjustable long delay protection, short delay protection, instantaneous protection, and ground fault protection settings.

In the open air at 40 degrees Celsius (104 degrees Fahrenheit), the HLD3600T106W MCCB can operate continuously at up to 600 Amps. It will conduct this amount of current without exceeding a 50 degrees Celsius maximum temperature at the line and input terminals. Its OPTIM 1050 trip unit encompasses thermal temperature-protective mechanisms that start a trip operation as a self-protection feature if the internal ambient temperature reaches approximately 90 degrees Celsius (184 degrees Fahrenheit). In the case of overheating, a thermal memory effect will prevent this item from being reenergized immediately. The users must wait approximately 5 minutes for the cabling’s internal temperature to cool down enough to be touched and repaired. This is a 3-phase protective HLD3600T106W that has 100 kAIC of interrupting capacity at 240 Volts AC and 65 kAIC of interrupting capacity at 480 Volts AC.


Technical specifications:


Part Number/Catalog No.HLD3600T106W
Product TypeMolded Case Circuit Breaker
SeriesC
FrameL
Poles3
Amps600 Amps
Interrupting Capacity100 kAIC at 240 Volts AC
Unit TypeOPTIM
Dimensions (W x H x D)8.25 x 10.75 x 4.06 inches
Weight20 pounds
Part Number/Catalog No.HLD3600T106W
Product TypeMolded Case Circuit Breaker
SeriesC
FrameL
Poles3
Amps600 Amps
Interrupting Capacity100 kAIC at 240 Volts AC
Unit TypeOPTIM
Dimensions (W x H x D)8.25 x 10.75 x 4.06 inches
Weight20 pounds