NDC312T106W

Preowned

Includes a 1-Year UrgentAutomation warranty.

UrgentAutomation is not an authorized distributor for GE Fanuc Emerson.

Rated 4.5 with 7 reviews

UrgentAutomation sells surplus and refurbished products which are sourced through independent channels. All warranties and support, if applicable, are with UrgentAutomation and not the manufacturer. UrgentAutomation is not an authorized distributor or representative for the listed manufacturers and makes no representations as to any quality control performed by any listed manufacturer on the products. The products listed on this website may vary as to their country of origin; the accessories, and other items included with the product; and the language used on the packaging, the parts, and any related instructions or printed material related to the products. This website is not sanctioned or approved by any manufacturer or tradename listed. Designated trademarks, brand names and brands appearing herein are the property of their respective owners. Read More


NDC312T106W

Description: The NDC312T106W Molded Case Circuit Breaker operates with 3 Poles and 1200 Amps. The module also has a N Frame and a Model 1050 Trip Model.

Preowned

Includes a 1-Year UrgentAutomation warranty.

UrgentAutomation is not an authorized distributor for GE Fanuc Emerson.


Description: The NDC312T106W Molded Case Circuit Breaker operates with 3 Poles and 1200 Amps. The module also has a N Frame and a Model 1050 Trip Model.


Rated 4.5 with 7 reviews







About NDC312T106W

The Eaton NDC312T106W is a Series G NDC type of circuit breaker with an NG frame. It is a 100% rated breaker with an HACR rating. The complete 3-pole NDC312T106W includes an OPTIM 1050 electronic LSIG type trip module. The OPTIM trip units are microprocessor-based, programmable, low-voltage trip units. OPTIM trip units cover a range of currents rated from 70 to 5000 Amps. They provide true RMS sensing and use a fixed interchangeable rating plug to determine the continuous current rating of a circuit breaker. The features available with the OPTIM 1050 are a digital display, current and power factor monitoring, monitoring of power or energy, and the monitoring of current harmonics. The communications protocol that is supported is the Eaton PowerNet protocol. The testing methods supported are the BIM, OPTIMizer, and the PowerNet.

The current rating of the NDC312T106W is 1200 Amps. The voltage rating is 600 Volts AC (at 50 and 60 Hertz frequency) and the interrupt specifications for the NDC312T106W are 100 kAIC at 480 Volts AC and 200 kAIC at 240 Volts AC. The molded case NDC312T106W circuit breaker is supplied without terminals. The terminals need to be purchased separately. Only the recommended cable types should be used. The use of unsupported cable types can cause personal injury or equipment damage due to short circuits. Overheating the terminals can cause damage to the breaker or spurious tripping. Therefore, joint solutions should be used with aluminum conductors to reduce the chance of overheating the terminals. The dimensions of the NDC312T106W are the following: 8.25 inches in height, 8.25 inches in width, and 5.5 inches in length. The circuit breaker weighs 48 pounds.


Technical specifications:


Part Number/Catalog No.NDC312T106W
Product TypeMolded Case Circuit Breaker
SeriesC
FrameN
Poles3
Amps1200 Amps
Trip ModelModel 1050
Trip TypeLSIG
Interrupting Capacity200 kAIC at 240 Volts AC
Dimensions (W x H x D)8.25 x 16 x 5.5 inches
Weight45 pounds
Part Number/Catalog No.NDC312T106W
Product TypeMolded Case Circuit Breaker
SeriesC
FrameN
Poles3
Amps1200 Amps
Trip ModelModel 1050
Trip TypeLSIG
Interrupting Capacity200 kAIC at 240 Volts AC
Dimensions (W x H x D)8.25 x 16 x 5.5 inches
Weight45 pounds
Common misspellings:
  • NDC3l2T106W
  • NDC312Tl06W
  • NDC312T1o6W